What was found
FLOOR SUPPORT FROM FR 68-69 AT -Y1292. REPLACED SUPPORT IAW SRM 51-72-11; TASK JA-260-53500, LEVEL 1, DEFECT SIZE: 3 SQ. IN.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR SUPPORT FROM FR 68-69 AT -Y1292. REPLACED SUPPORT IAW SRM 51-72-11; TASK JA-260-53500, LEVEL 1, DEFECT SIZE: 3 SQ. IN.