What was found
FOUND FLOORBEAM CORRODED, FS 66 - 64. REMOVED AND SPLICED NEW FLOORBEAM PER SRM 53-41-14, DWG NR D53472815; CORROSION TASK JA-260-53500, LEVEL 1 DEFECT SIZE: 3" BY 12".
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND FLOORBEAM CORRODED, FS 66 - 64. REMOVED AND SPLICED NEW FLOORBEAM PER SRM 53-41-14, DWG NR D53472815; CORROSION TASK JA-260-53500, LEVEL 1 DEFECT SIZE: 3" BY 12".