What was found
TOP SIDE OF FLOORBEAM AT FR 66 (FWD OF LT DOOR SILL) CORRODED. ROUTED OUT CORROSION, INSTALLED FILLER PIECE PER SRM 53-41-14 FIG 201; CORR TASK JA-260-53500, DEFECT SIZE: 1 X 1 INCH.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TOP SIDE OF FLOORBEAM AT FR 66 (FWD OF LT DOOR SILL) CORRODED. ROUTED OUT CORROSION, INSTALLED FILLER PIECE PER SRM 53-41-14 FIG 201; CORR TASK JA-260-53500, DEFECT SIZE: 1 X 1 INCH.