STRINGER 16L BETWEEN STATION 348 AND 351 CRACKED. FABRICATED AND INSTALLED NEW INTERCOSTAL IAW SRM 51-10-02 DRAWING 69-16970, DEFECT SIZE: .125 INCH.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STRINGER 16L BETWEEN STATION 348 AND 351 CRACKED. FABRICATED AND INSTALLED NEW INTERCOSTAL IAW SRM 51-10-02 DRAWING 69-16970, DEFECT SIZE: .125 INCH.