What was found
STA 380 FRAME AT UPPER FLANGE BETWEEN STR S20L AND S21L CRACKED. REMOVED DAMAGE AND INSTALLED REPAIR PARTS IAW SRM 51-70-11, DEFECT SIZE: 1 INCH.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STA 380 FRAME AT UPPER FLANGE BETWEEN STR S20L AND S21L CRACKED. REMOVED DAMAGE AND INSTALLED REPAIR PARTS IAW SRM 51-70-11, DEFECT SIZE: 1 INCH.