What was found
NUMEROUS AREAS AROUND SCREW HOLES, TOP OF FLOORBEAM STA 377.7 CORRODED. INSTALLED T-CAP & SPLICE ANGLES PER SRM 53-00-51; CORR TASK JL-46-53500; LEVEL 1 DEFECT SIZE: 2.75 INCHES.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
NUMEROUS AREAS AROUND SCREW HOLES, TOP OF FLOORBEAM STA 377.7 CORRODED. INSTALLED T-CAP & SPLICE ANGLES PER SRM 53-00-51; CORR TASK JL-46-53500; LEVEL 1 DEFECT SIZE: 2.75 INCHES.