What was found
FUSELAGE BS 400, STRIGNER 16L HAS DENT. INSTALLED DOUBLER REPAIR AT LEFT BS 400, MATERIAL USED, 7075-T6, .063 INCH, 21 INCH BY 11 INCH. REPAIR ACCOMPLISHED IAW SRM 53-30-3 FIGURE 1. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FUSELAGE BS 400, STRIGNER 16L HAS DENT. INSTALLED DOUBLER REPAIR AT LEFT BS 400, MATERIAL USED, 7075-T6, .063 INCH, 21 INCH BY 11 INCH. REPAIR ACCOMPLISHED IAW SRM 53-30-3 FIGURE 1. (M)