What was found
FOUND ANGLE CRACKED, STR 14L, STA 360, AT LOCK FASTENER COMMON TO TIE CLIP JUST FWD OF FRAME 360. FAB'D NEW ANGLE PER SRM 51-10-02 PER SR 51-10-02, DEFECT SIZE: .5".
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND ANGLE CRACKED, STR 14L, STA 360, AT LOCK FASTENER COMMON TO TIE CLIP JUST FWD OF FRAME 360. FAB'D NEW ANGLE PER SRM 51-10-02 PER SR 51-10-02, DEFECT SIZE: .5".