What was found
SEVERAL; AREAS, BS 312 - 354, S-17: Z-CHORD ANGLE AT FWD, ENTRY DOOR SILL HAS CORROSION. INSTALLED NEW ANGLE PER SRM 51-10-02, 51-20-00; CORR TASK C53-107-01, CORR LEVEL 2, DEFECT SIZE: 1 X 1 INCH.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SEVERAL; AREAS, BS 312 - 354, S-17: Z-CHORD ANGLE AT FWD, ENTRY DOOR SILL HAS CORROSION. INSTALLED NEW ANGLE PER SRM 51-10-02, 51-20-00; CORR TASK C53-107-01, CORR LEVEL 2, DEFECT SIZE: 1 X 1 INCH.