What was found
VERT STIFFENER ATTACH ANGLE, AFT SIDE OF BS 328 FLOORBEAM AT LBL 45. REMOVED CRACKED ANGLE AND REPLACED WITH NEW PART PER SRM 51-10-02 DEFECT SIZE: 1/8".
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
VERT STIFFENER ATTACH ANGLE, AFT SIDE OF BS 328 FLOORBEAM AT LBL 45. REMOVED CRACKED ANGLE AND REPLACED WITH NEW PART PER SRM 51-10-02 DEFECT SIZE: 1/8".