What was found
BETWEEN BS 500 & BS 400, STR 28L & 28R UNDER CHANNEL HAS CORROSION. REPAIRED PER BOEING DWG 65-45783, SRM 51-10-02; CORR TASK C53-208-01, DEFECT SIZE: 4 X 6 INCHES.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BETWEEN BS 500 & BS 400, STR 28L & 28R UNDER CHANNEL HAS CORROSION. REPAIRED PER BOEING DWG 65-45783, SRM 51-10-02; CORR TASK C53-208-01, DEFECT SIZE: 4 X 6 INCHES.