What was found
STA 344 - 312 FWD ENTRY WAY, LT SIDE HAS CORROSION. REPLACED DAMAGED Z-ANGLE WITH NEW PER SRM 51-10-02, 51-40-03; CORR TASK C53-107-02, DEFECT SIZE: .750 INCH.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STA 344 - 312 FWD ENTRY WAY, LT SIDE HAS CORROSION. REPLACED DAMAGED Z-ANGLE WITH NEW PER SRM 51-10-02, 51-40-03; CORR TASK C53-107-02, DEFECT SIZE: .750 INCH.