What was found
FOUND DURING C-CHECK, RIGHT MAIN WHEEL WELL STATION 870, PRESSUER WEB HAS 3 INCH CRACK JUST OUTBOARD OF KEEL BEAM. INSTALLED WEB REPAIR AT RIGHT MAIN WHEEL WELL RIGHT OF STATION 870, LOWER WEB INBOARD. MATERIAL USED, 2024-T3, .040 INCH, 14 INCH BY 6 INCH. REPAIR ACCOMPLISHED IAW SRM 53-10-9 FIG 4. INSTALLED ALSO REPAIR DOUBLERS AT RIGHT WHEEL WELL STATION 870 PRESSURE WEB, RIGHT APU CUTOUT. MATERIAL USED, 15-5PH STEEL, .050 INCH, 12 INCH BY 6 INCH, 21 INCH BY 18.5 INCH. REPAIR ACCOMPLISHED IAW SRM 53-10-9 FIG 5. 9M0