What was found
A 1 INCH CRACK FOUND AT STA 161, LBL 45 FLOORBEAM. REPLACED 20 INCH SECTION OF FLOORBEAM STABILIZER PER TR 53-35-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
A 1 INCH CRACK FOUND AT STA 161, LBL 45 FLOORBEAM. REPLACED 20 INCH SECTION OF FLOORBEAM STABILIZER PER TR 53-35-01.