Service difficulty report · Flow Valve · Emb ERJ190100IGW

Difficulty date
December 13, 2008
Submitted
December 15, 2008
Operation
Air carrier
Aircraft
N964UW
Make and model
Emb ERJ190100IGW
Aircraft serial
19000197
Part
Flow Valve
Part number
10014566
Part serial
1807
Condition
Inoperative
Location
A/C Pack
Part time
825 hours, 711 cycles
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FLIGHT 1772, CLT-DFW - AFTER TAKEOFF THE AIRCRAFT WAS UNABLE TO PRESSURIZE. THE CREW WAS PERFORMING OPS PROC WITH ECS OFF THE APU BLEED CLOSED PROPERLY AT 500FT, LEFT BLEED OPENED MOMENTARILY BUT THEN CLOSED RESULTING IN THE FOLLOWING EICAS MESSAGES; "X BLEED FAIL", "BLEED 1 OFF", "PACK 2 OFF", AND "BLEED APU VALVE". THE FLIGHT REMAINED BELOW 15,000 FEET WITH THE APU POWERING PACK 1. MAINTENANCE THE NR 2 PACK CONTROL VALVE.

More about the Emb ERJ 190-100 IGW