What was found
SAL - Q6 - MAJOR REPAIR - CRACK ON FLOORBEAM SUPPORT "T" CHORD UPPER FLANGE AT BS 727 +17 INCHES, RBL 24.75. REPAIRED FLOORBEAM SUPPORT "T" CHORD UPPER FLANGE AT BS 727 +17 INCHES, RBL 24.75 IAW US AIRWAYS EA 132351.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SAL - Q6 - MAJOR REPAIR - CRACK ON FLOORBEAM SUPPORT "T" CHORD UPPER FLANGE AT BS 727 +17 INCHES, RBL 24.75. REPAIRED FLOORBEAM SUPPORT "T" CHORD UPPER FLANGE AT BS 727 +17 INCHES, RBL 24.75 IAW US AIRWAYS EA 132351.