What was found
FLT 631 - PIT - LAS - EMERGENCY EQUIPMENT - DOOR L1, R1, L2 & R2 SLIDES WILL NOT ARM PROPERLY. PERFORMED OPERATIONAL CHECK ON DOOR R1, R2, & L2 AND TESTED GOOD. ADJUSTED TARGET FOR 13WV1 ON DOOR L1 PER MAINTENANCE MANUAL 52-71-00-820-00. OPERATIONAL CHECK WAS GOOD.