What was found
SAL - MAJOR REPAIR - BC7 CHECK - LEVEL 2 GALVANIC CORROSION ON FLOORBEAM AT FR 67+15 INCHES TO FR 70, -Y1292. REPLACED FLOORBEAM AT FR 67+15 INCHES TO FR 70, -Y1292 IAW A320 SRM 51-72-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SAL - MAJOR REPAIR - BC7 CHECK - LEVEL 2 GALVANIC CORROSION ON FLOORBEAM AT FR 67+15 INCHES TO FR 70, -Y1292. REPLACED FLOORBEAM AT FR 67+15 INCHES TO FR 70, -Y1292 IAW A320 SRM 51-72-11.