What was found
MAJOR REPAIR - NR 6154383 - LEVEL 2 CORROSION ON FLOORBEAM AT FR 64 +9 INCHES, Y 765. REPLACED FLOORBEAM BETWEEN FR 64 TO FR 66, Y765 IAW SRM 51-72-11 DWG D53472000. (K)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAJOR REPAIR - NR 6154383 - LEVEL 2 CORROSION ON FLOORBEAM AT FR 64 +9 INCHES, Y 765. REPLACED FLOORBEAM BETWEEN FR 64 TO FR 66, Y765 IAW SRM 51-72-11 DWG D53472000. (K)