What was found
SAL - S5 - MAJOR REPAIR - LEVEL 2 GALVANIC CORROSION ON FLOORBEAM BETWEEN FR67 + 15 INCHES TO FR69, Y1162. REPLACED FLOORBEAM BETWEEN FR67 + 15 INCHES TO FR69, Y1162 IAW A320 SRM 51-72-11 & AIRBUS DRAWING D53472000.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SAL - S5 - MAJOR REPAIR - LEVEL 2 GALVANIC CORROSION ON FLOORBEAM BETWEEN FR67 + 15 INCHES TO FR69, Y1162. REPLACED FLOORBEAM BETWEEN FR67 + 15 INCHES TO FR69, Y1162 IAW A320 SRM 51-72-11 & AIRBUS DRAWING D53472000.