What was found
CLT - MAJOR REPAIR - Q5 CHECK - LEVEL 2 EXFOLIATION CORROSION ON THE FORWARD ENTRY DOOR CUTOUT LOWER SILL Z-ANGLE AT BS 306 - BS 360, LBL 54. REPLACED THE FORWARD ENTRY DOOR CUTOUT LOWER SILL Z-ANGLE AT BS 306 - BS 360, LBL 54 IAW B737 SRM 51-10-02.