What was found
PIT - C1 - EES - JOB CARD # 43T20025001 - DURING R-2 DOOR EMERGENCY EVACUATION SLIDE TEST, PNEUMATIC ASSEMBLY DID NOT FULLY OPEN DOOR WITH 2200 PSI. REMOVED CLEANED & REINSTALLED PNEUMATIC ASSEMBLY PLUNGER & SPRING ASSEMBLY.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - C1 - EES - JOB CARD # 43T20025001 - DURING R-2 DOOR EMERGENCY EVACUATION SLIDE TEST, PNEUMATIC ASSEMBLY DID NOT FULLY OPEN DOOR WITH 2200 PSI. REMOVED CLEANED & REINSTALLED PNEUMATIC ASSEMBLY PLUNGER & SPRING ASSEMBLY.