What was found
PIT - S2 - MAJOR REPAIR - LEVEL 2 CORROSION ON UPPER SURFACE OF FLOORBEAM BETWEEN FR18 TO FR20, -Y1292. REPLACED FLOORBEAM BETWEEN FR18 TO FR20, -Y1292 IAW A319 SRM 51-41-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - S2 - MAJOR REPAIR - LEVEL 2 CORROSION ON UPPER SURFACE OF FLOORBEAM BETWEEN FR18 TO FR20, -Y1292. REPLACED FLOORBEAM BETWEEN FR18 TO FR20, -Y1292 IAW A319 SRM 51-41-11.