What was found
PIT - MAJOR REPAIR - S4 - LEVEL 2 GALVANIC CORROSION ON SHEAR PLATE BETWEEN FR 69-70, STR 23R. REPLACED SHEAR PLATE BETWEEN FR 69-70, STR 23R IAW A319 SRM 51-72-11, 51-42-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - MAJOR REPAIR - S4 - LEVEL 2 GALVANIC CORROSION ON SHEAR PLATE BETWEEN FR 69-70, STR 23R. REPLACED SHEAR PLATE BETWEEN FR 69-70, STR 23R IAW A319 SRM 51-72-11, 51-42-11.