What was found
PIT - MAJOR REPAIR - S4 - LEVEL 2 GALVANIC CORROSION ON FLOORBEAM BETWEEN FR 64-66 AND FR 68 -70 STR 23R, BL -Y1292. REPLACED FLOORBEAM BETWEEN FR 64-66 AND FR 68 -70 STR 23R, BL -Y1292 IAW A319 SRM 51-72-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - MAJOR REPAIR - S4 - LEVEL 2 GALVANIC CORROSION ON FLOORBEAM BETWEEN FR 64-66 AND FR 68 -70 STR 23R, BL -Y1292. REPLACED FLOORBEAM BETWEEN FR 64-66 AND FR 68 -70 STR 23R, BL -Y1292 IAW A319 SRM 51-72-11.