What was found
PIT - MAJOR REPAIR - SY6/C11 CHECK - LEVEL 2 GALVANIC CORROSION ON FLOOR SUPPORT AT FR 16- FR 20, -Y254. REPLACED FLOOR SUPPORT AT FR 16- FR 20, -Y254 IAW A319 SRM 51-42-11 AND 51-72-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - MAJOR REPAIR - SY6/C11 CHECK - LEVEL 2 GALVANIC CORROSION ON FLOOR SUPPORT AT FR 16- FR 20, -Y254. REPLACED FLOOR SUPPORT AT FR 16- FR 20, -Y254 IAW A319 SRM 51-42-11 AND 51-72-11.