What was found
PIT - MAJOR REPAIR - SY6/C11 CHECK - LEVEL 2 GALVANIC CORROSION ON FLOORBEAM AT FR 16 - FR 20, +Y1292. REPLACED FLOORBEAM AT FR 16 - FR 20, +Y1292 IAW A319 SRM 51-42-11 AND 51-41-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - MAJOR REPAIR - SY6/C11 CHECK - LEVEL 2 GALVANIC CORROSION ON FLOORBEAM AT FR 16 - FR 20, +Y1292. REPLACED FLOORBEAM AT FR 16 - FR 20, +Y1292 IAW A319 SRM 51-42-11 AND 51-41-11.