As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
SAL - MAJOR REPAIR - S5 - LEVEL 2 GALVANIC CORROSION ON FLOORBEAM BETWEEN FR 66 +5 INCHES TO FR67 +15 INCHES, Y1292. REPLACED FLOORBEAM BETWEEN FR 66 +5 INCHES TO FR67 +15 INCHES, Y1292 IAW A320 SRM 51-72-11 AND AIRBUS DRAWING 53472000.