What was found
SAL - MAJOR REPAIR - S4 CHECK - LEVEL 2 GALVANIC CORROSION ON RAIL DUMMY BEAM AT -Y503.2, FR 14. REPLACED RAIL DUMMY BEAM AT -Y503.2, FR 14 IAW A319 SRM 51-72-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SAL - MAJOR REPAIR - S4 CHECK - LEVEL 2 GALVANIC CORROSION ON RAIL DUMMY BEAM AT -Y503.2, FR 14. REPLACED RAIL DUMMY BEAM AT -Y503.2, FR 14 IAW A319 SRM 51-72-11.