What was found
PIT - SY6-C11 - MAJOR REPAIR - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR18 + 3.75 INCHES TO FR18 + 6 INCHES, Y1292. REPLACED FLOORBEAM BETWEEN FR18 + 3.75 INCHES TO FR18 + 6 INCHES, Y1292 IAW A319 SRM 53-11-15.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - SY6-C11 - MAJOR REPAIR - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR18 + 3.75 INCHES TO FR18 + 6 INCHES, Y1292. REPLACED FLOORBEAM BETWEEN FR18 + 3.75 INCHES TO FR18 + 6 INCHES, Y1292 IAW A319 SRM 53-11-15.