What was found
CWF - MAJOR REPAIR - S2 CHECK - CORROSION ON SEAT TRACK AT FR 39.1 + 11.5, +Y450, Z=0. REPLACED SEAT TRACK AT FR 39.1 + 11.5, +Y450, Z=0. AFTER FURTHER REVIEW BY THE ENGINEERING DEPARTMENT IT WAS DETERMINED THAT THIS EVENT WAS CPCP RELATED AND CLASSIFIED AS A LEVEL 2 FINDING.