What was found
CLT - Q3 - MAJOR REPAIR - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM AT BS 986.5 BETWEEN LBL 24 TO LBL 40. REPAIRED FLOORBEAM AT BS 986.5 BETWEEN LBL 24 TO LBL 40 IAW EA 40627A.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.