As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
PIT - FPBH - MAJOR REPAIR - CRACK ON MAIN ENTRY DOOR UPPER HINGE CUTOUT BEAR STRAP AT BS 304 BETWEEN WL 262.75 TO WL 258.50. REPAIRED MAIN ENTRY DOOR UPPER HINGE CUTOUT BEAR STRAP AT BS 304 BETWEEN WL 262.75 TO WL 258.50 IAW EA 117319.