What was found
PIT - S4 - LEVEL 2 GALVANIC CORROSION ON PASSENGER FLOOR SHEAR TIE BETWEEN FR20 TO FR24, -Y1732. REPLACED FLOORBEAM IAW A319 SRM 51-40-00.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - S4 - LEVEL 2 GALVANIC CORROSION ON PASSENGER FLOOR SHEAR TIE BETWEEN FR20 TO FR24, -Y1732. REPLACED FLOORBEAM IAW A319 SRM 51-40-00.