What was found
PIT - S4 - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR66 TO FR68, -Y765. REPLACED FLOORBEAM BETWEEN FR66 TO FR68, -Y765 IAW A319 SRM 53-41-14.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - S4 - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR66 TO FR68, -Y765. REPLACED FLOORBEAM BETWEEN FR66 TO FR68, -Y765 IAW A319 SRM 53-41-14.