What was found
CWF - S4 - LEVEL 2 EXFOLIATION CORROSION ON FLOOR SUPPORT AT FR66 + 4 INCHES, -Y384. REPLACED FLOOR SUPPORT AT FR66 + 4 INCHES, -Y384 IAW A319 SRM 51-42-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CWF - S4 - LEVEL 2 EXFOLIATION CORROSION ON FLOOR SUPPORT AT FR66 + 4 INCHES, -Y384. REPLACED FLOOR SUPPORT AT FR66 + 4 INCHES, -Y384 IAW A319 SRM 51-42-11.