What was found
BFM - S4 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR 65 TO FR 67, BL Y1292. REPLACED FLOORBEAM BETWEEN FR 65 TO FR 67, BL Y1292 IAW A319 SRM 53-00-14, 51-42-11, 51-44-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BFM - S4 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR 65 TO FR 67, BL Y1292. REPLACED FLOORBEAM BETWEEN FR 65 TO FR 67, BL Y1292 IAW A319 SRM 53-00-14, 51-42-11, 51-44-11.