What was found
BFM - S4 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM 4 INCHES FORWARD OF FR 68, BL Y1292. REPLACED FLOORBEAM 4 INCHES FORWARD OF FR 68, BL Y1292 IAW A319 SRM 53-00-14 FIG 102, 51-42-11, 51-75-12.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BFM - S4 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM 4 INCHES FORWARD OF FR 68, BL Y1292. REPLACED FLOORBEAM 4 INCHES FORWARD OF FR 68, BL Y1292 IAW A319 SRM 53-00-14 FIG 102, 51-42-11, 51-75-12.