What was found
OIL SMELL THROUGHOUT ENTIRE AIRCRAFT REPORTED AFTER LANDING IN CANCUN. MAINTENANCE FOUND APU GENERATOR LEAKING. REMOVED AND REPLACED GENERATOR PER AIRBUS MAINTENANCE MANUAL 24-20-00. ACCOMPLISHED ECS DECONTAMINATION.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
OIL SMELL THROUGHOUT ENTIRE AIRCRAFT REPORTED AFTER LANDING IN CANCUN. MAINTENANCE FOUND APU GENERATOR LEAKING. REMOVED AND REPLACED GENERATOR PER AIRBUS MAINTENANCE MANUAL 24-20-00. ACCOMPLISHED ECS DECONTAMINATION.