What was found
2S CHECK - LEVEL 2 EXFOLIATION CORROSION ON 3 SQ IN CORROSION CABIN FLOOR PANEL 231AF ATTACH FLANGE AT FR21 TO FR22 & BETWEEN Y720 TO -Y720. REPLACED CABIN FLOOR PANEL 231AF ATTACH FLANGE IAW A319 SRM 51-42-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
2S CHECK - LEVEL 2 EXFOLIATION CORROSION ON 3 SQ IN CORROSION CABIN FLOOR PANEL 231AF ATTACH FLANGE AT FR21 TO FR22 & BETWEEN Y720 TO -Y720. REPLACED CABIN FLOOR PANEL 231AF ATTACH FLANGE IAW A319 SRM 51-42-11.