Service difficulty report · Shutoff Valve · Emb ERJ190100IGW

Difficulty date
July 17, 2011
Submitted
July 18, 2011
Operation
Air carrier
Aircraft
N947UW
Make and model
Emb ERJ190100IGW
Aircraft serial
19000078
Part
Shutoff Valve
Part number
10012463
Part serial
2008060323
Condition
Inoperative
Location
Bleed Air Sys
Part time
5,454 hours, 4,594 cycles
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FLIGHT 706, ORD-PHL - AT 30,000FT AND CLIMBING BLEED 2 ANNUNCIATED. RAN QRH CHECKLIST AND BLEED 2 CAME BACK ON. FINISHED CHECKLIST THAT REQUIRED CREW TO CLOSE NR 1 AND NR 2 BLEEDS, APU BLEED AND CROSSBLEED. EICAS STILL INTERMITTENTLY ANNUNCIATED. PER QRH PROCEDURE THE AIRPLANE DESCENDED DOWN TO 10,000FT AND DEPRESSURIZED. THE FLIGHT DIVERTED TO PIT FOR MAINTENANCE. MAINTENANCE REMOVED AND REPLACED THE NR 2 ENGINE PRSOV PER MM 36-11-03. NO LEAKS NOTED, AC OK FOR SERVICE.