What was found
C11 CHECK - LEVEL 2 INTERGRANULAR CORROSION ON FLOORBEAM AT FR12, -Y50. REPLACED FLOORBEAM AT FR12, -Y50 IAW A319 SRM 51-42-00.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
C11 CHECK - LEVEL 2 INTERGRANULAR CORROSION ON FLOORBEAM AT FR12, -Y50. REPLACED FLOORBEAM AT FR12, -Y50 IAW A319 SRM 51-42-00.