What was found
C4 CHECK - LEVEL 2 GALVANIC CORROSION ON FLOOR SUPPORT BETWEEN BS 1661 TO BS 1701 LBL 54. REPLACED FLOOR SUPPORT BETWEEN BS 1661 TO BS 1701 LBL 54 IAW B757 SRM 51-10-02, 53-00-51 & 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
C4 CHECK - LEVEL 2 GALVANIC CORROSION ON FLOOR SUPPORT BETWEEN BS 1661 TO BS 1701 LBL 54. REPLACED FLOOR SUPPORT BETWEEN BS 1661 TO BS 1701 LBL 54 IAW B757 SRM 51-10-02, 53-00-51 & 51-40-02.