What was found
Q3 CHECK - LEVEL 2 EXFOLIATION CORROSION ON AFT GALLEY FLOOR PAN BETWEEN BS 1016 +10 INCHES TO BS 1016 +16 INCHES & BETWEEN LBL 2 TO RBL 2. REPAIRED AFT GALLEY FLOOR PAN IAW B737 SRM 51-70-13 & BOEING DRAWING 65C32677.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
Q3 CHECK - LEVEL 2 EXFOLIATION CORROSION ON AFT GALLEY FLOOR PAN BETWEEN BS 1016 +10 INCHES TO BS 1016 +16 INCHES & BETWEEN LBL 2 TO RBL 2. REPAIRED AFT GALLEY FLOOR PAN IAW B737 SRM 51-70-13 & BOEING DRAWING 65C32677.