What was found
S2 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR20 TO FR23, -Y189. REPLACED FLOORBEAM BETWEEN FR20 TO FR23, -Y189 IAW A319 SRM 51-72-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
S2 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR20 TO FR23, -Y189. REPLACED FLOORBEAM BETWEEN FR20 TO FR23, -Y189 IAW A319 SRM 51-72-11.