What was found
C11/SY6 CHECK - LEVEL 2 EXFOLIATION CORROSION ON THRESHOLD SHAPE SILL FITTING AT FR 67, -Y1589. REPLACED THRESHOLD SHAPE SILL FITTING AT FR 67, -Y1589 IAW A319 SRM 51-72-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
C11/SY6 CHECK - LEVEL 2 EXFOLIATION CORROSION ON THRESHOLD SHAPE SILL FITTING AT FR 67, -Y1589. REPLACED THRESHOLD SHAPE SILL FITTING AT FR 67, -Y1589 IAW A319 SRM 51-72-11.