What was found
2S CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR64+10 INCHES & FR66, Y1292. REPLACED FLOORBEAM BETWEEN FR64+10 INCHES & FR66, Y1292 IAW A319 SRM 53-00-14 & 51-49-00.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
2S CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR64+10 INCHES & FR66, Y1292. REPLACED FLOORBEAM BETWEEN FR64+10 INCHES & FR66, Y1292 IAW A319 SRM 53-00-14 & 51-49-00.