2S CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR68 TO FR69, Y1162. REPLACED FLOORBEAM BETWEEN FR68 TO FR69, Y1162 IAW A319 SRM 53-00-14 FIG 102 & 51-49-00.