Service difficulty report · Valve · Airbus A320214

Difficulty date
October 5, 2011
Submitted
October 7, 2011
Operation
Air carrier
Aircraft
N118US
Make and model
Airbus A320214
Aircraft serial
1264
Aircraft time
35,506 hours, 15,645 cycles
Part
Valve
Part number
6740E010000
Part serial
000918
Condition
Faulty
Location
Bleed Air Sys
Part time
35,508 hours, 15,646 cycles
Stage of operation
CR
How discovered
O
Nature of condition
B, J
Precautionary procedure
H

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AIR - ENG 2 BLEED FAULT IN CRUISE ACCOMPANIED BY A HOT BURNING SMELL IN CABIN & COCKPIT. CREW ACCOMPLISHED ECAM - QRH PROCEDURES - SHUTDOWN ENG 2 BLEED FOR REMAINDER OF FLIGHT. MAINTENANCE REPLACED OVERPRESSURE VALVE IAW AIRBUS MAINTENANCE MANUAL 36-11-53.