C11 CHECK - AIRCRAFT FAILS EMERGENCY LIGHTING SYSTEM TEST 33-51-00-710-001. CLEANED EMERGENCY POWER SUPPLY UNIT CONNECTOR AS REQUIRED. OPS CHECKED GOOD IAW A319 AMM 33-51-00-710-001.